BIP W-100R: A-60 Class Bulkhead
BIP Industries Co., Ltd. Goseong| W-100R Verified manufacturer
0.3 kcal/㎡h℃MED (Wheelmark), SOLAS Compliant, IMO FTP Code A-60
IMO FTP Code MED SOLAS
Thermal Transmittance
0.3 kcal/㎡h℃
Certification
MED (Wheelmark), SOLAS Compliant, IMO FTP Code
Fire Rating Class
A-60
Core Insulation Material
Mineral Wool 140 kg/m³
The BIP W-100R: A-60 Class Bulkhead is a certified non-load bearing vertical fire-retarding division engineered for specialized marine boundary partitions. Manufactured in compliance with SOLAS regulations and the IMO 2010 FTP Code, it provides high-integrity A-60 class fire protection.
The system consists of bulkhead panels insulated with a 98.5 mm thick mineral wool core (nominal density of 140 kg/m³, manufactured by KCC Corporation). Along the vertical sides of the panel, higher-density mineral wool (240 kg/m³, manufactured by KCC Corporation) is fitted from the edge and 50 mm into the panel. The insulation is fixed to 0.6 mm thick steel sheets by means of an adhesive. The panels are joined together with cap profiles on both sides and fitted to 1.2 mm thick steel profiles at the bottom and top, with the top profile fitted with an additional 25 mm mineral wool layer (140 kg/m³), bringing the total panel thickness to 100 mm.
Note: Use of this product is limited to applications specifically approved by the Administration in question (see IMO 2010 FTP Code Annex 1, Part 3, Items 1.12 and 1.13) and shall not be used as part of main fire zone bulkheads and stairways enclosures on passenger ships (see also IMO MSC/Circ. 1005).
The system consists of bulkhead panels insulated with a 98.5 mm thick mineral wool core (nominal density of 140 kg/m³, manufactured by KCC Corporation). Along the vertical sides of the panel, higher-density mineral wool (240 kg/m³, manufactured by KCC Corporation) is fitted from the edge and 50 mm into the panel. The insulation is fixed to 0.6 mm thick steel sheets by means of an adhesive. The panels are joined together with cap profiles on both sides and fitted to 1.2 mm thick steel profiles at the bottom and top, with the top profile fitted with an additional 25 mm mineral wool layer (140 kg/m³), bringing the total panel thickness to 100 mm.
Note: Use of this product is limited to applications specifically approved by the Administration in question (see IMO 2010 FTP Code Annex 1, Part 3, Items 1.12 and 1.13) and shall not be used as part of main fire zone bulkheads and stairways enclosures on passenger ships (see also IMO MSC/Circ. 1005).
| Thermal Transmittance | 0.3 kcal/㎡h℃ |
| Facing Material | 0.6 mm Steel Sheet |
| Certification | MED (Wheelmark), SOLAS Compliant, IMO FTP Code |
| Length | 3000 mm |
| Width | 600 mm |
| Fire Rating Class | A-60 |
| Core Insulation Material | Mineral Wool 140 kg/m³ |
| Areal Density / Weight | 27.3 kg/m² |
| Thickness | 100 mm |